Liquid Chromatography with Indirect UV Detection for Determination of Some Inorganic Anions Using a Permanently Coated Column: Determination of Monofluorophosphate, Phosphate and Iodide
 
More details
Hide details
1
Helwan University, Faculty of Pharmacy, Analytical Chemistry Department, Cairo, Egypt
CORRESPONDING AUTHOR
Mohamed Salem Rizk   

College of Pharmacy Helwan University, Ain Helwan – Cairo (POB 11795), Egypt
Online publication date: 2008-03-01
Publication date: 2008-03-01
 
Eurasian J Anal Chem 2008;3(2):223–235
 
KEYWORDS
ABSTRACT
A method for the separation and determination of inorganic anions using a reversed phase column permanently coated with n-cetylpyridinium chloride is described. A 1 mM sodium salicylate solution in 5% (v/v) methanol was used as the mobile phase. The separation of some inorganic anions (monofluorophosphate (MFP), phosphate and iodide) was carried out in about 10 minutes. Detection was made using indirect UV detection at 290 nm. Satisfactory reproducibility of the results was obtained even after a four months period of continual use of the column. Through the evaluation of the analytical parameters, the method was linear (r = 0.999) at concentrations ranging from 10.0 to 100.0 μg mL-1.
 
REFERENCES (20)
1.
Ito K, Ariyoshi Y, Tanabiki F and Sunahara H (1991) Anion chromatography using octadecylsilane reversed-phase columns coated with hexadecyltrimethylammonium and its application to nitrite and nitrate in sea-water. Anal. Chem. 63(3): 273.
 
2.
Michigami Y and Yamamoto Y (1992) Behaviour of the system peak in ion chromatography with indirect ultra-violet absorption detection and trimellitate as eluent. J. Chromatogr. A. 623(1): 148.
 
3.
Jun X, Lima J L F C and Montenegro M C B S M (1997) A study of a permanently coated polymeric column for simultaneous separation of inorganic anions and monocarboxylic acids. Anal. Chim. Acta. 339(3): 231.
 
4.
Krokhin O V , Svintsova N V , Obrezkov O N and Shpigun O A (1997) Modified silica gel for the determination of anions by single-column ion chromatography. J. Anal. Chem. (Transl. of Zh. Anal. Khim). 52(11): 1066.
 
5.
Ito K, Shoto E and Sunahara H (1991) Ion chromatography of inorganic iodine species using C18 reversed-phase columns coated with cetyltrimethylammonium. J. Chromatogr. A. 549: 265.
 
6.
Ito K, Ariyoshi Y and Sunahara H (1992) Determination of inorganic anions in salt solutions by ion chromatography using C18 reversed-phase columns coated with cetyltrimethylammonium. J. Chromatogr. A. 598 (2): 237.
 
7.
Ohta K and Tanaka K (1995) Retention behaviour of inorganic anions and organic acids on a polymer-coated C18 column coated with cetyltrimethylammonium ion by ion chromatography with indirect UV spectrophotometric detection. Bunseki Kagaku 44(9): 713.
 
8.
Ito K (1997) Separation behaviour of inorganic anions on an octadecyl-bonded silica column coated with cetyltrimethylammonium by phthalate and salicylate eluents. J. Chromatogr. A. 764(2): 346.
 
9.
Nagashima H and Okamoto T (1999) Determination of inorganic anions by ion chromatography using a graphitized carbon column dynamically coated with cetyltrimethylammonium ions. J. Chromatogr. A. 855 (1): 261.
 
10.
Yoshikawa K, Okamura M, Inokuchi M and Sakuragawa A (2007) Short communication. Ion chromatographic determination of organic acids in food samples using a permanent coating graphite carbon column. Talanta 72 (1): 305.
 
11.
Lei Z, Tian S and Cheng J (1989) Column coated with hexadecylpyridinium for separation of inorganic anions by ion-interaction [reversed-phase] chromatography. Sepu 7(1): 44.
 
12.
Jun X, Lima J L F C and Montenegro M C B S M (1996) Simultaneous determination of inorganic anions and carboxylic acids in wine using isocratic separation on a permanently coated reversed-phase column and UV indirect detection. Anal. Chim. Acta. 321 (2-3): 263.
 
13.
Michigami Y, Morooka M and Ueda K (1996) Short communication. Determination of sulphite and sulphate by ion chromatography using a weakly basic phthalate eluent. J. Chromatogr. A. 732 (2): 403.
 
14.
Li J, Zhu Y and Guo Y (2006) 18th Annual International Ion Chromatography Symposium. Fast determination of anions on a short coated column. J. Chromatogr. A. 1118 (1): 46.
 
15.
Pavic M, Carevic D and Cimerman Z (1999) Potentiometric determination of monofluorophosphate in dentifrice: a critical discussion and a proposal for new improved procedures. J. Pharm. Biomed. Anal. 20(3): 565.
 
16.
Tsang S, Phu F, Baum M M and Poskrebyshev G A (2007) Determination of phosphate/arsenate by a modified molybdenum blue method and reduction of arsenate by S2O4 2− . Talanta 71 (4): 1560.
 
17.
Koh T and Ono M (1988) Determination of iodide by ion-pair method with methylene blue. Analyst 113: 945.
 
18.
Cassidy R M and Elchuk S (1985) Fixed-site ion exchanger for liquid chromatographic determination of multifunctional carboxylic acids Anal. Chem. 57: 615.
 
19.
Hackzell L, Rydberg T and Schill G (1983) Construction of systems for detection and quantitation by UV-absorbing mobile-phase ions in reversed-phase chromatography J. Chromatogr. A. 282: 179.
 
20.
Gao J, Yang W, Kang J, Hou J and Bian H (1997) Anion separation by high-performance ion chromatography coupled with indirect photometric detection and 1,2-dihydroxybenzene-3,5-disulfonate or sodium sulfosalicylate as the eluent J. Chromatogr. A. 789(1-2): 195.
 
eISSN:1306-3057