Monitoring of Trace Metals in Biological Samples Using Electrochemical Nanosensors Prior to Anodic Stripping Votammetry
 
More details
Hide details
1
Department of Chemistry, S.V.University, Tirupati 517502 A.P, India
CORRESPONDING AUTHOR
Yugandha Sreedhar Neelam   

Department of Chemistry, S.V.University, Tirupati 517502 A.P, India
Publish date: 2017-10-27
 
Eurasian J Anal Chem 2010;5(2):152–160
KEYWORDS
ABSTRACT
The present paper out line the simultaneous determination of lead and zinc using electrochemical nanosensors like electrochemical conjugated polymers Ecp’s which is prepared by polymerization process and its application in biological samples. In this work the metal ions were complexed with a newly sysnthesised analytical reagent 4-(2-hydroxy phenyl ethaminodiol), benzene-1.3-diol (4-2-HPEDB-1,3,D) and analysis was carried out by anodic stripping voltammetry. Electrochemical characteristics like scan rate, deposition potential, deposition time, effect of pH were studied under optimized conditions. The calibration curve was constructed with in the range of 0.05–200 µg/ml-1 at pH 4.0 (acetate buffer) having correlation factor as 0.9964 for lead, 0.9992 for zinc and RSD will found to be 5.3 %.The study of interfering ions during the analysis of lead and zinc with the error of >2%, shows the sensitivity and selectivity of the proposed method. The Accuracy and precision of the proposed method was checked by the analysis of certified reference material and results were pertained in this paper.
 
REFERENCES (15)
1.
Jankiewicz B P, Wieczorek M (2001) Spectrophotometric determination of lead in the soil of allotment gardens. Polish Journal of Environmental Studies 10(2): 123.
 
2.
Anant P. Argekar and Ashok K. Shetty (1998) Extraction of lead(II) with cyanex 302 and its spectrophotometric determination with PAR. Talanta 45(5): 909-915.
 
3.
Jin Z, Shougui J, Shikun C, Desen J, Chakraborti D (1990) Direct determination of lead in human blood and selenium, cadmium, copper, zinc in serum by electrothermal atomic absorption spectrophotometry using Zeeman effect background correction. Fresenius J Anal Chem 337(8): 877.
 
4.
Ghaedi M, Tavallali H, Shokrollahi A, Zahedi M,. Niknam K, Soylak M (2009) Preconcentration and Determination of Zinc and Lead Ions by a Combination of Cloud Point Extraction and Flame Atomic Absorption Spectrometry. Clean-Soil, Air, Water See Also. 37(4-5): 328.
 
5.
Ghaedi M, Shokrollahi A, Niknam K, Niknam E, Derki S, Soylak M (2009) A Cloud Point Extraction Procedure for Preconcentration/Flame Atomic Absorption Spectrometric Determination of Silver, Zinc, and Lead at Subtrace Levels in Environmental Samples. J AOAC 92(3):907-13.
 
6.
Kennedy frost J,Santoliquido P M, Camp L R, Ruch R R (1975) Trace Elements in Coal by Neutron Activation Analysis with Radiochemical Separations. Advances in Chemistry 141: 84–97.
 
7.
Jung M C, Thornton I, Chon H T (1998) Arsenic, Cadmium, Copper, Lead, and Zinc Concentrations in Cigarettes Produced in Korea and the United Kingdom. Environmental Technology 19(2): 237–241.
 
8.
Batista B L, Rodrigues J L, Nunes J A, Tormen L, Curtius A J, Barbosa F (2008) Simultaneous determination of Cd, Cu, Mn, Ni, Pb and Zn in nail samples by inductively coupled plasma mass spectrometry (ICP-MS) after tetramethylammonium hydroxide solubilization at room temperature Comparison with ETAAS. Talanta 76(3): 575-579.
 
9.
Gercken B, Barnes R M (1991) Determination of lead and other trace element species in blood by size exclusion chromatography and inductively coupled plasma/mass spectrometry. Anal Chem 63 (3): 283.
 
10.
Snow A W, Mario G, Ancona, Kruppa W, Jernigan G G, Foos E E, Doe Park (2002) Self-assembly of gold nanoclusters on micro- and nanoelectronic substrates. J Mater Chem 12: 1222.
 
11.
Sigaud M, Li M, Chardon-Noblat S, José Cadete Santos Aires F, Soldo-Olivier Y, Simon J P, Renouprez A, Deronzier A (2004) Electrochemical preparation of nanometer sized noble metal particles into a polypyrrole functionalized by a molecular electrocatalyst precursor. J Mater Chem 14: 2606.
 
12.
Marc A. Breimer, Gelfand Yevgeny, Sheldon S, Sadik O A (2001) Incorporation of Metal Nanoparticles in Photopolymerized Organic Conducting Polymers: A Mechanistic Insight. Nano Letters 1 (6): 305 -308.
 
13.
Shervedani R K, Ahmad S (2005) Preparation and electrochemical characterization of a new nanosensor based on self-assembled monolayer of cysteamine functionalized with phosphate groups. Mozaffari Surface and Coatings Technology 198(1-3): 123- 128.
 
14.
Shervedani R K, Mozaffari S A (2006) Copper(II) Nanosensor Based on a Gold Cysteamine Self-Assembled Monolayer Functionalized with Salicylaldehyde. Anal. Chem. 78 (14):4957–4963.
 
15.
Sumner J P, Westerberg N M, Stoddard A K, Fierke C A, Sensors R K, Actuators B (2006) Cu+ - and Cu2+-sensitive PEBBLE fluorescent nanosensors using DsRed as the recognition element. Chemical 113(2): 760-767.
 
eISSN:1306-3057