ASSAY METHOD DEVELOPMENT AND VALIDATION OF MINOXIDIL FILM-COATED TABLETS.

Authors

  • Syeda Firdouse Fathima
  • Shaik Gouse Ul Azam
  • S Shahida Bee

Keywords:

Minoxidil, RP-HPLC, Chromatographic Method, Assay Development, Method Validation

Abstract

A robust and precise reverse-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for the quantitative determination of Minoxidil in film-coated tablets. Chromatographic separation was achieved using an X-Bridge C18 column (150 mm x 4.6 mm ID, 5 μm). The mobile phase consisted of a buffer and acetonitrile mixture in a 55:45 (v/v) ratio. The diluent was prepared using water and acetonitrile in a 50:50 (v/v) ratio, while the needle wash solution was a 90:10 (v/v) acetonitrile-water mixture. The method employed a flow rate of 1.0 mL/min, a detection wavelength of 280 nm, an injection volume of 10 μL, and a column temperature of 40°C in isocratic pump mode. Minoxidil had a retention time of 6.6 minutes, with a total run time of 10 minutes. The assay exhibited a Minoxidil percentage range of 97%-102%, with an r² value of 1.000 for the concentration range tested. The %RSD values were less than 2%, indicating high accuracy and precision. The method demonstrated robustness within acceptable limits and was validated in accordance with ICH Q2 guidelines.

Author Biographies

  • Syeda Firdouse Fathima

    Research scholar, Department of Pharmaceutical analysis, Safa College of Pharmacy, Kurnool

  • Shaik Gouse Ul Azam

    Research scholar, Department of Pharmaceutical analysis, Safa College of Pharmacy, Kurnool

  • S Shahida Bee

    Associate Professor, Department of Pharmaceutical Chemistry, Safa College of Pharmacy, Kurnool

References

Ali AH. High-performance liquid chromatography (HPLC): a review. Ann. Adv. Chem. 2022;6:010-20.

Tiwari G, Tiwari R. Bioanalytical method validation: An updated review. Pharm Methods. 2010 Oct;1(1):25-38. doi: 10.4103/2229-4708.72226. PMID: 23781413; PMCID: PMC3658022.

Aboul-Kheir A Hanna Saleh, Magda M. Henawee –EI, Sharif M.N El-D. Bromometric analysis of Lamotrigine, Mnoxidil and Cefixime. Asian J. Pharm. Ana. 2012;2(1):22-28.

Hemant K Gaidhane1, Jagadish P Bidada2, Akshaya S Bhusari3, Manjusha S NavkhareGanesh P Diwanka H Tiwari 1- Development and validation of stability Indicating HPLC Method for the estimation of Minoxidil and released Sbstances in topical formulation. Minoxidil- Wikipedia, the free encyclopedia en. Wikipedia.org /wiki/Minoxidil.

Zahid A Zaheer, Shahed Mirza, Ismail Moazzam and Imran W Sayad RafiqZakaria Campus, Maulana Azad Educational Trust`s, Y. B. Chavan College of Pharmacy, Rauza Bagh, Aurangabad (Maharashtra) India -A Journal of Scholar research Library- UV-Spectrophotometric determination of Minoxidil and its application to the assay in Pharmaceutical Dosage forms- Available online at www.derpharmachemica.com, (http://derpharmachemica.com/archive.html).